DEEP CABLEDEEP CABLEDEEP CABLE

Coaxial Cable

Coaxial Cable

Feature

Coaxial cables are widely used to transmit electrical energy, or signals, from one location to another: to connect a source to a load, such as a transmitter to an antenna. These cables consist of two conductors separated by a dielectric material. Special class insulation material is used to provide separation between the conductors. We supply an array of coaxial cable in different construct such as core solid/ stranded, tinned/bare, copper/CCS/CCA, etc.

Coaxial Cable

Feature

Coaxial cables are widely used to transmit electrical energy, or signals, from one location to another: to connect a source to a load, such as a transmitter to an antenna. These cables consist of two conductors separated by a dielectric material. Special class insulation material is used to provide separation between the conductors. We supply an array of coaxial cable in different construct such as core solid/ stranded, tinned/bare, copper/CCS/CCA, etc.

Cat. No. Type Characteristic Impedance Ohms Capacitance Maxi. pF/m Maxi. db/100 f 200 MHz Maxi. db/100 m 200 MHz Inner conductor* Dia. in mm Dielectric Insulation Dia.in mm Overall Dia.in mm
RG-58 C/U RG-58 C/U 50+-2 105 10.5 34.4 0.90 (ft) 2.95 (2Y) 4.95 (Y)
RG-58 C/U (Speacial) RG-58 C/U 50+-2 105 11.5 37.95 0.78 (ft) 2.70 (2Y) 4.95 (Y)
RG-174A/U RG-174A/U 50+-2 105 0.48 (ft) 1.50 (2Y) 2.80 (Y)
RG-178 B/U RG-178 B/U 50+-2 95 19.39 64 0.30 (fv) 0.86 (5Y) 1.91 (6Y)
RG-188 A/U RG-188 A/U 50+-2 95 14.54 48 0.51 (fv) 1.52 (5Y) 2.8 (5Y)
RG-213 /U RG-213 /U 50+-2 101 3.3 10.8 2.26(fb) 7.25 (2Y) 10.30 (Y)
RG-214 /U (DS) RG-214 /U 50+-2 101 2.9 9.5 2.26 (ft) 7.25(2Y) 10.80 (Y)
RG-223 /U (DS) RG-223 /U 50+-2 106 8.8 28.9 0.89(sv) 2.95 (2Y) 5.40 (Y)
RG-11 A/U RG-11 A/U 75+-3 68 1.75 5.8 1.63(sb) 7.50 (2Y) 10.5 (Y)
RG-8 A/U RG-8 A/U 75+-3 68 2.72 9 1.12 (sb) 6.0  (2Y) 8.5 (YY)
RG-6 A/U RG-6 A/U 75+-3 68 3.18 10.5 0.91 (sb) 4.80 (2Y) 5.8 (YY)
RG-59 A/U RG-59 A/U 75+-3 68 4.09 13.5 0.71(sb) 3.80 (2Y) 5.0 (YY)
RG-59 B/U RG-59 B/U 75+-3 68 3.78 12.5 0.71 (st) 3.40(2Y) 6.0 (Y)
RG-59 B/U (DS) RG-59 B/U 75+-3 68 3.48 11.5 0.71(st) 3.40 (2Y) 6.5 (Y)
RG-187A/U RG-187A/U 75+-3 65 14.24 47 0.31(fv) 1.52 (5Y) 2.80 (5Y)
RG-62 A/U RG-62 A/U 93+-5 43 5 16.5 0.65 (sb) 3.7(3Y) 6.20 (Y)
RG-71 B/U (DS) RG-71 B/U 93+-5 43 3.93 13 0.65 (sb) 3.7(3Y) 6.50 (2Y)
Insulation Specification: 
Y : PVC, YY :Double PVC sheathing, 2Y : PE-Solid insulation, 3Y : PE-Air spaced insulation,
(Dielectric/ Sheath) :
5Y : fluorine polymere PTEF, 6Y : fluorine polymere FEP,

Conductor Specification:
s :solid conductor, f :flexible/ stranded conductor, b :bare copper, t :tinned plated, v :silver plated

LMR Flexible Low Loss Plenum(LLPL) Coax Cable
Cat. No.
Type
Characteristic
Impedance
Ohms
Capacitance
Maxi. pF/m
Maxi.
db/100 f
220 MHz
Maxi.
db/100 m
220 MHz
Inner
conductor*
Dia. in mm
Dielectric
Insulation
Dia.in mm
Overall
Dia.in mm
LMR-200 LMR-200 50+-2            
LMR-220 LMR-220 50+-2            
LMR-240 LMR-240 50+-2            
LMR-300 LMR-300 50+-2            
LMR-400 LMR-400 50+-2 87.6 1.9 6.1 2.41 7.24 10.29
LMR-500 LMR-500 50+-2            
Corrugated Copper tube outer conductor type Coax Cable
Cat. No. Capacitance
Maxi. pF/m
Maxi.
db/100 f
220 MHz
Maxi.
db/100 m
220 MHz
Inner
conductor*
Dia. in mm
Dielectric
Insulation
Dia.in mm
Overall
Dia.in mm
1/2" (HCTAY-50-12) 50+-2          
7/8" (HCTAY-50-22) 50+-2          
1-1/4" (HCTAY-50-22) 50+-2          
1-5/8" (HCTAY-50-42) 50+-2          
RGB / VJ Cables With Overall Braid Shielded & Al-foil Shield
Cat. No.
No. of
Coxial Size14/38)
No. of
Cores
Size 7/36
Characteristic
Impedance
Ohms
Capacitance
Maxi. pf/m
Maxi.
db/100 f
at 200 MHz
Maxi.
db/100 m
at 200 MHz
Dielectric
Insulation
Dia.in mm
Outer Dia.
OverSheath
in mm
  3+7 VJ 3 7            
  3+8 VJ 3 8